TÜV AUTOMOTIVE GMBH       Oaimlerstral1e 11
  Unternehmensgruppe                  0-85748 Garching
TÜV Süddeutschland

Telefon O 89 / 329 50 - 680 Telefax O 89/329 50 - 650

TÜV

AUTOMOTIVE

Test Report No.:
Applicant:
Type:

352 - 0001 - 04 FBTN PERSA San. Tic. Ltd. Sti. without

  Page 1

 

Test Report


No. 352 - 0001 - 04 FBTN

Test according to the directive of the council of the European Community on the ap­proximation of the laws of the Member States relating to

the burning behaviour of materials used in the interior eonstruetion of eertain eategories of motor vehiele


No. 95/28/EC dated 24.10.1995

ı.       Teehnieal Deseription    

Applicant:

 

 

PERSA Poliüretan ve Koltuk Sistemleri San. Tic. Ltd. StL
Minarelicavus Mahallesi Dökümcüler Sitesi 11. Sk. No. 48

TR - 16140 BURSA
Type:   without
Base material(s) / designation :   Voralux HW ­ Polyol
Specflex NR - fsocyante
Composite / single material, number of layers :   single material
Type of coating :   not applicable
Maximum / minimum thick­ness :   no Iimitation

 

Akkreditiert unter DAR-Registriernummer KBA-P-00001-95
von der Akkreditierungsstelle des Kraftfahrt-Bundesamtes, Bundesrepublik Deutschland

 

TÜV AUTOMOTIVE GMBH       Oaimlerstral1e 11
  Unternehmensgruppe                  0-85748 Garching
TÜV Süddeutschland

Telefon O 89 / 329 50 - 680 Telefax O 89/329 50 - 650

TÜV

AUTOMOTIVE

Test Report No.:
Applicant:
Type:

352 - 0001 - 04 FBTN PERSA San. Tic. Ltd. Sti. without

  Page 2

 

Test Report

Testing of the burning behaviour of interior materials according to 95/28/EC
                 ~              Appendix IV
                 D             AppendixV
                 D             Appendix VI
 

11.2.      Test results:
                 ~              The requirements concerning the burning behaviour according to
annex IVNI are met. They were verified in
                                    ~           horizontal directian (Annex IV)
                                   D           vertical directian (Annex VI)
                                   D           horizontal and vertica/ directian (Annex IV and VI)
                                   D           The requirements concerning the melting behaviour according to Annex V are met.
 

11.3.      Comments:
Horizontal burning rate < 52 mm/min
 

11.4.      Date of the Test:

22.01.2004

 

B000104A.MEN

 
 


TÜV Automotive GmbH D-85744
Garching Unternehmensgruppe
TÜV Süddeutschland